(A+E-81F) Tube/Flange Electromagnetic Water Flowmeter
A+E 81F Intelligent Electromagnetic Flowmeter is an all-intelligent flowmeter manufactured
And developed by our company, adopting the latest advanced technology both at home and
Abroad. It has much distinction to the old-fashioned analog or non-intelligent electromagnetic
Flowmeter, especially in terms of measurement accuracy, reliability, functions and service life.
Features
1) The flow measurement will not be impacted by changes of the density, viscosity,
Temperature, pressure and conductivity of liquid, and the induced voltage signal of
Sensor has linear relationship with flow rate, so the measurement accuracy is very high.
2) There is no baffles within the measuring pipes, so there is no additional pressure loss
And there is no moveable parts within the measuring pipes, so the service life of the
Sensor is extremely long.
3) The only part of sensor that contacts the measured liquid is the lining and the electrode.
As long as you choose the proper electrode and lining material, the product can be
Anti-corrosion and wear-resistance.
4) This converter adopts the latest and most advanced single chip (MCU) and SMT internationally,
And it has the advantages of reliable performances, high accuracy, low power comsumption,
Stable components, and convenient parameter setting. Click on the Chinese LCD to indicate
The accumulated flow rate, instantaneous flow rate, flow velocity and flow percentage etc.
5) Using the two-way measurement system, to measure the positive flow and the negative flow.
To make sure that the product performance can remain stable in a long period of time, the
Product adopts special production process and high-quality material.
This Electromagnetic Flowmeter can be used to measure the volume flow rate of conducting
Liquid and seriflux in closed pipes, such as pure water, sewage, all kinds of acid-alkali-salt
Solution, slurry, pulp, paper pulp and food liquids.
Technical Parameter:
1. Flow Velocity Range: 0.1~15m/s
2. Flow Direction: Positive, negative, net flow
3. Accuracy Grade: 0.2%, ± 0.3%, ± 0.5%
4. Repeatability: ± 0.1%, ± 0.15%, ± 0.25%
5. Working Pressure: ≤ 0.6Mpa(DN1100~2200)
≤ 1.0Mpa(DN200~1000)
≤ 1.6Mpa(DN100~150)
≤ 0.6Mpa(DN10~80)
Customized for special pressure
6. Output signal: Standard current 4~20mA, full isolation, load resistance<750Ω
7. Fluid temperature: E grade<80 degree
H grade <180 degree
8. Impulse Frequency: 0~1kHz, Optoelectronic isolation OST, external power
Supply≤ 35V. When it is connected
9. Protection Grade: IP65 IP68
10. Output function: Positive and negative direction, net flow signal
11. Electrode material: Stainless steel, Plantium, Hastelloy (B, C), Tantalum, Titanium
12. Flange material: Carbon steel, stainless steel,
13. Meter body material: Carbon steel, stainless steel
14. Alarm (normally open): Empty pipe, excitation, the upper and lower limit of flow rate.
15. Working power supply: Single phase alternating current 85~265V, 45~63Hz,
Power<20W; DC 24V10VA
16. Electrode form: Standard, scraper, removable